OPERATION MANUAL
CLASSIC 40 and CLASSIC 60
Unit Serial Number Range: 0711XXXX### to Present
(From July 2011 to Present)
READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT
INSTALLATION AND USAGE, AND READ ALL SAFEGUARDS
SECCIÓN EN ESPAÑOL
SECTION EN FRANÇAIS
AVAILABLE AT WWW.MOVINCOOL.COM
Zobrazit stránku 0
1 2 3 4 5 6 ... 45 46

Shrnutí obsahu

Strany 1 - OPERATION MANUAL

OPERATION MANUALCLASSIC 40 and CLASSIC 60Unit Serial Number Range: 0711XXXX### to Present(From July 2011 to Present)READ THIS MANUAL CAREFULLY FOR INS

Strany 2 - Nameplate Label

10INSTALLATION (cont.)Exterior DimensionsClassic 402.837.84xM202.830.141.34.86.95.110.05.125.8DIA. 13.8DIA. 22.010.020.712.943.55.110.24.36XM62X6XM622

Strany 3

11INSTALLATION (cont.)Exterior Dimensions (cont.)Classic 608.729.94xDIA. 0.53.533.85.17.131.53.1 25.2 3.1DIA. 25.1DIA. 13.811.522.015.849.431.79.38.58

Strany 4 - Table of Contents

12INSTALLATION (cont.)Choosing an Installation SiteCAUTION: Following are some precautions to consider before choosing your installation site. Please

Strany 5 - FOREWORD

13INSTALLATION (cont.)Plugging in the Unit (For Classic 40 ONLY)1. Check the prongs and surface of the power cord plug for dust/dirt. If dust and/or d

Strany 6 - INVENTORY & ASSEMBLY

14INSTALLATION (cont.)Power Supply and Field Wiring Connection (For Classic 60 ONLY)Power Supply• AC 460 V±10 %, 3 phase and 60 Hz. Do not connect the

Strany 7 - Inventory (cont.)

15INSTALLATION (cont.)Power Supply and Field Wiring Connection (For Classic 60 ONLY) (cont.)Power Supply Wires• Use at least 12 AWG for the power wire

Strany 8 - M6 BOLTS (8)

16INSTALLATION (cont.)Optional Accessories and Set Up ConfigurationUsing the optional accessories not only gives you the ability to customize the cool

Strany 9 - INSTALLATION

17INSTALLATION (cont.)Optional Accessories and Set Up Configuration (cont.)Unit Installed on the Floor (For Classic 40 and Classic 60) 2. Application

Strany 10 - DIA. 22.0

18INSTALLATION (cont.)Optional Accessories and Set Up Configuration (cont.)Unit Suspended from the Ceiling (For Classic 40 ONLY)When the unit is suspe

Strany 11 - DIA. 26.2

19INSTALLATION (cont.)Optional Accessories and Set Up Configuration (cont.)Unit Suspended from the Ceiling (For Classic 40 ONLY)1. Standard Configurat

Strany 12

SERIAL NUMBER LOCATION AND IDENTIFICATIONNameplate Label PositionNameplate LabelCOOLING AMPS. WITH PUMPCOMPR. OUTPUTREFRIGERANT/TOTAL CHARGEDESIGN PRE

Strany 13

20INSTALLATION (cont.)Optional Accessories and Set Up Configuration (cont.)Unit Suspended from the Ceiling (For Classic 40 ONLY)2. Application Configu

Strany 14

21INSTALLATION (cont.)Optional Accessories and Set Up Configuration (cont.)Unit Suspended from the Ceiling (For Classic 40 ONLY)3. Duct Work Procedure

Strany 15

22INSTALLATION (cont.)Optional Accessories and Set Up Configuration (cont.)Unit Used as a Portable TypeThe unit can be used as a portable spot cooling

Strany 16

23INSTALLATION (cont.)Optional Accessories and Set Up Configuration (cont.)Outdoor Installation of the Unit (For Classic 40 and Classic 60)The unit ca

Strany 17 - 2. Application Configuration

24INSTALLATION (cont.)Wall Thermostat Connection (Millivolt System ONLY: Option)Connecting Wall Thermostat to Unit1. Use with a single stage wall ther

Strany 18

25INSTALLATION (cont.)Wall Thermostat Connection (Millivolt System ONLY: Option) (cont.)Connecting Wall Thermostat to Unit4. Set the wall thermostat t

Strany 19

26INSTALLATION (cont.)Wall Thermostat Connection (Millivolt System ONLY: Option) (cont.)Connecting Wall Thermostat to Unit8. Install the wall thermost

Strany 20

27INSTALLATION (cont.)Warning Signal Connection (Output Signal Terminal L+ and L-)The controller is equipped with a warning signal output relay type (

Strany 21

28INSTALLATION (cont.)Warning Signal Connection (Output Signal Terminal L+ and L-) (cont.)Connecting Warning Signal from Controller3. Insert the warni

Strany 22

29INSTALLATION (cont.)Fire Alarm Control Panel Connection (Input Signal Terminal E+ and E-)The controller is equipped with a normal open input signal

Strany 23

OPERATION MANUALCLASSIC 40 and CLASSIC 60

Strany 24

30INSTALLATION (cont.)Fire Alarm Control Panel Connection (Input Signal Terminal E+ and E-) (cont.)Connecting Fire Alarm Control Panel to Controller3.

Strany 25 - GYWRCRHOB

31OPERATIONFeatures1. A digital electronic control panel, which allows the user to easily control the unit’s operation.2. Digital LED display that ind

Strany 26

32OPERATION (cont.)Control PanelBefore operating the unit, it is important to familiarize yourself with the basic controls located on the control pane

Strany 27

33OPERATION (cont.)Control Panel (cont.)LED Display DescriptionsIn normal operation, the LED displays the following descriptions.Note: The ROOM TEMP d

Strany 28

34OPERATION (cont.)Operating ModesThe Classic 40 and Classic 60 can be operated in two modes, FAN ONLY and COOL. When in FAN ONLY mode, the unit circu

Strany 29

35OPERATION (cont.)Operating in COOL Mode1. The unit can be operated in COOL mode by pressing the COOL ON/OFF button.Note: In COOL mode the unit can o

Strany 30

36OPERATION (cont.)Self-Diagnostic CodesSelf-diagnostic codes are displayed on the control panel under the following conditions.Contact your MovinCool

Strany 31 - OPERATION

37DAILY INSPECTION & MAINTENANCEClean the Air FiltersClean the air filters once a week. If the unit is used in a dusty environment, more frequent

Strany 32 - OPERATION (cont.)

38DAILY INSPECTION & MAINTENANCE (cont.)In-Season/Off-Season Inspection & MaintenanceWARNING: To prevent an accident due to electrical shock,

Strany 33 - Control Panel (cont.)

39DAILY INSPECTION & MAINTENANCE (cont.)In-Season/Off-Season Inspection & Maintenance (cont.)Off-Season1. Operate the unit in FAN ONLY mode fo

Strany 34

Table of ContentsSERIAL NUMBER LOCATION AND IDENTIFICATION ... 2FOREWORD ...

Strany 35

40TROUBLESHOOTINGCheck the following items before calling your MovinCool reseller or a qualified technician.CONDITION POSSIBLE CAUSE REMEDYUnit does n

Strany 36 - Self-Diagnostic Codes

41TROUBLESHOOTING (cont.)If conditions persist after the above actions have been taken, turn the unit off, disconnect the power and contact your Movin

Strany 37 - Filter Removal Method

42TROUBLESHOOTING (cont.)Installation Check SheetITEMS 9Installation Unit Check and make sure all screws are tight and unit is secured in place.Check

Strany 38 - In-Season

43TECHNICAL SPECIFICATIONS*1: Rated at external static pressure 0.63 IWG (157 Pa).*2: Rated at external static pressure 0 IWG (0 Pa).*3: Rated at exte

Strany 39 - Off-Season

44TECHNICAL SPECIFICATIONS (cont.)ITEMS/FEATURES Classic 40 Classic 60Safety DevicesCompressor overload protectorFan motor protectorAnti-freezing ther

Strany 40

WARRANTY STATEMENTDENSO PRODUCTS AND SERVICES AMERICAS, INC. ("DENSO") warrants its MOVINCOOL Products only to the extent stated in its offi

Strany 41

P/N: 484007-3621EN Second Issue: April 2013

Strany 42 - Installation Check Sheet

5FOREWORDCongratulations on purchasing the MovinCool spot cooling system. This manual explains how to assemble, install and operate the MovinCool Clas

Strany 43

6INVENTORY & ASSEMBLYInventoryClassic 40After unpacking your MovinCool unit, please check to make sure you have the following items:1. Classic 40

Strany 44

7INVENTORY & ASSEMBLY (cont.)Inventory (cont.)Classic 60After unpacking your MovinCool unit, please check to make sure you have the following item

Strany 45 - WARRANTY STATEMENT

8INVENTORY & ASSEMBLY (cont.)Assembly of Exhaust Duct (For Classic 60 ONLY)1. Remove the exhaust duct from the package.2. Install the exhaust duct

Strany 46

9INSTALLATIONUnit OverviewClassic 40Classic 60EXHAUST DUCTCOOL AIR OUTLETAIR FILTERSCONTROL PANELPOWER CORDEXHAUST DUCTCOOL AIR OUTLETCONTROL PANELAIR

Komentáře k této Příručce

Žádné komentáře